ELECTRICAL CALIBRATION

Slide 1
ELECTRICAL CALIBRATION

Onsite calibrations, new equipment sales, and expedited service options

Instrument Calibration Solutions (ICS), a Brechbuhler Scales company, provides ISO/IEC 17025 accredited electrical calibration for multimeters, clamp meters, oscilloscopes, power analyzers, insulation testers and more. Calibrations are traceable to NIST and are performed in our Clayton, OH and Aliquippa, PA laboratories or by our mobile calibration lab based in Canton, OH, which comes to your facility.

Every ICS lab, including the mobile lab, can perform all of the electrical calibrations listed below. We also offer new equipment sales and expedited service options.

Our electrical calibration standards

Our electrical lab is built around a Fluke 5522A and 5520 multi-product calibrator with scope pack. The 5522A sources DC and AC voltage and current, including multiple waveforms and harmonics, two simultaneous voltage outputs, or voltage and current together to simulate DC and AC power with phase control. It also sources resistance, capacitance, and thermocouple and RTD signals, and it can measure thermocouple temperature and pressure using any of our 29 Fluke 700 Series pressure modules. The scope pack adds oscilloscope calibration.

ICS is a Brechbuhler Scales company, so your calibration is backed by the local branch support you already know.

electrical icon

Our electrical capabilities include but are not limited to:

  • Handheld and Bench Meters (analog and digital)
  • Thermocouple and RTD Thermometers
  • Process Calibrators
  • Data Loggers
  • Strip and Chart Recorders
  • Watt Meters
  • Power/Harmonic Analyzers
  • Current Clamps and Clamp Meters
  • Analog or Digital Handheld and Bench Oscilloscopes (with options)
  • Panel Meters
  • High Pots … Insulation Testers

Electrical calibration FAQs

How often should a multimeter or clamp meter be calibrated?

Most manufacturers and quality systems specify every 12 months. Shorten the interval for critical measurements, after a drop or overload, or if the last calibration found the instrument out of tolerance. Your quality system sets the final interval.

What does ISO/IEC 17025 accreditation mean for my audit?

ANAB accreditation means an independent body has assessed the laboratory's technical competence, equipment and measurement uncertainty. ISO 9001, AS9100 and IATF 16949 audits expect calibration that is traceable to national standards, and accredited calibration is the most direct way to show it. The ICS accreditation certificate is linked at the top of this page.

What is "as found" and "as left" data?

As-found data is how an instrument measured before any adjustment, and as-left data is how it measures afterward. If the as-found readings are out of tolerance, you may need to review measurements taken since the last calibration.

Can you calibrate on-site?

Yes. Our mobile calibration lab, based in Canton, OH, comes to your facility and can perform all of the electrical calibrations listed above. You can also send instruments to our Clayton, OH or Aliquippa, PA laboratory.

What can the Fluke 5522A calibrate?

The 5522A sources DC and AC voltage and current, resistance, capacitance, and thermocouple and RTD signals, and it simulates DC and AC power with phase control. With the scope pack it also calibrates oscilloscopes.

Do you offer expedited service?

Yes. Expedited service options are available. Call the branch number listed on this page for your area.

Do you sell new electrical test equipment?

Yes. In addition to calibration, we offer new equipment sales.

Related calibration services

Electrical instruments are often used with other measurements. See our temperature and humidity calibration for thermocouples, RTDs and probes, and our pressure calibration for gauges, transducers and transmitters.